VDI 6022 and hygiene in ventilation systems

VDI 6022 and hygiene in ventilation systems – the engineering standard for clean air, energy efficiency, and reliable operation of air handling units and energy recovery heat exchangers

 

In modern low-energy buildings, the ventilation system is no longer just a means of supplying air. It is a system of critical importance that determines indoor environmental quality, energy efficiency, and the operational reliability of the building. For this reason, across Europe—and increasingly in Bulgaria—the VDI 6022 standard is being applied more frequently. It sets strict requirements for the hygiene of ventilation and air-conditioning systems, including air handling units, energy recovery units, ductwork, filtration, and humidification.

 

This standard is used as a reference in the design of:

  • hospitals and cleanrooms
  • pharmaceutical manufacturing facilities
  • schools and public buildings
  • factories and industrial facilities
  • office and administrative buildings
  • data centers
  • low-energy buildings (nZEB / ZEB)

 

 

  1. What does VDI 6022 require from an engineering perspective?

VDI 6022 defines the hygiene requirements for manufacturers regarding:

  • The design of air handling units and the potential for air leakage (infiltration)
  • The internal surfaces that are in contact with the treated air
  • Filtration stages and air purification
  • Condensate drainage
  • Humidification and cooling
  • Operation and maintenance (service)
  • The accessibility for cleaning, maintenance, and inspection of every component in the installation

The core principle of VDI 6022 is: The ventilation system must not degrade the air quality for occupants under any operating conditions. It must improve the indoor climate.

  1. The air handling unit is the key element for the hygiene of the ventilation system.

The air-handling equipment in a building consists of air handling units. This is where the air is filtered, cooled or heated, humidified or dehumidified, and where heat recovery takes place. If it is not manufactured in accordance with VDI 6022, it can lead to the growth of microorganisms, retention or ingress of dust, accumulation of condensate and odors, corrosion, and the transfer of contaminants.

 

Therefore, air handling units must have:

  • double-skin panels with a smooth internal surface
  • no exposed fibrous materials
  • sloped bases for drainage
  • inspection doors or panels for individual sections
  • high-durability seals
  • filters with appropriate filtration efficiency and proper sealing
  • plate or rotary heat exchangers with an efficiency above 73% (according to EN 308)
  • heat exchangers with access for cleaning
  • siphons and condensate drains
  • high-efficiency fans with variable (stepless) control according to demand
  • anti-corrosion coatings
  • materials resistant to disinfection

TANGRA AHU air handling units are designed specifically for such applications and comply with the requirements of VDI 6022, DIN 1886, DIN 1946, Eurovent, and TÜV. They are used in various facilities with high demands for air cleanliness and system reliability across 18 countries in Europe. They can be manufactured in a hygienic version for systems in hospitals, clean production environments, and the food industry, as well as in a standard version for administrative and office buildings, factories, and industrial facilities.

 

  1. Energy recovery units manufactured in accordance with VDI 6022 also provide efficiency without compromising hygiene.

Modern buildings require high energy efficiency, making heat recovery essential. However, with improper design, the heat recovery unit can become a source of contaminated air transfer, transmission of viruses and bacteria, moisture retention in rooms, and the transfer of unpleasant odors. For this reason, TANGRA follows the requirements of VDI 6022 both for its TANGRA AHU air handling units and for its TANGRA EVB energy-saving units. The characteristics, as well as the installation method of each component, are designed in accordance with VDI 6022 requirements. Plate or rotary heat exchangers, bypass (free-cooling) systems, sealing between the two air streams, high-efficiency fans, and filtration elements are all of the highest class.

 

 

 

A properly designed and manufactured energy recovery unit must provide users with:

  • high energy efficiency (≥73%, according to EN 308)
  • high-efficiency fans with demand-based control
  • filtration systems ensuring zero contamination transfer and no possibility of leakage or infiltration
  • easy cleaning and inspection access
  • corrosion resistance
  • proper condensate drainage

TANGRA EVB energy recovery units are designed to combine high heat exchange efficiency (≥75%, according to EN 308), with their performance data verified in the Eurovent laboratory in Switzerland. Durability and reliable operation even under industrial conditions, as well as serviceability and easy inspection, are also key characteristics of TANGRA products. This is particularly important when selecting equipment for schools, hospitals, office buildings, production facilities, laboratories, and public buildings.

 

  1. The relationship between hygiene, standards, and operational costs:

Practice in Europe shows that ventilation systems which are not properly designed, or which use equipment that does not comply with the requirements of VDI 6022, DIN 1886, and EN 13053, as well as systems that have not been tested by an independent certification body (such as TÜV, Eurovent, or another accredited laboratory), often fail to meet the required hygiene and operational criteria.

 

As a result, in real operation, accumulation of contaminants on internal surfaces of the equipment, growth of bacteria and microorganisms, increased pressure drop, reduced energy recovery efficiency, corrosion of heat exchangers and structural components, and difficult access for cleaning and maintenance are observed. These issues lead to serious consequences for the building investor and end user, including:

  • increased operating costs
  • more frequent service interventions
  • shorter equipment lifespan
  • risk of system shutdown
  • degraded indoor air quality
  • possible health problems for occupants

Engineering practice shows that systems which do not comply with VDI 6022 requirements, or which lack verification from an independent third-party certification body, lead to:

  • more frequent filter replacement
  • higher pressure drop
  • higher energy consumption by fans
  • corrosion of heat exchangers
  • expensive repairs
  • risk of system shutdown

Conversely, when equipment is properly manufactured in accordance with VDI 6022, DIN 1886, and good European practice, fans operate against lower resistance, heat exchangers remain clean for longer periods, there are no conditions for biological contamination, maintenance is easier, less frequent, and less costly, and the service life of the systems is longer.

 

In many cases, the use of air handling units and energy recovery units with proven quality and certification by an independent third party leads to a significant reduction in operating costs over the entire lifecycle of the system, with the difference potentially reaching tens of percent compared to systems without certified hygienic design.

 

  1. Why do investors in Europe, and increasingly in Bulgaria, require VDI 6022 compliance or equipment tested by independent certification bodies?

The reasons behind every investor’s focus on cost are clear. Increasingly across Europe, and also in Bulgaria, there is a growing emphasis on the quality of products used in ventilation and air-conditioning systems. It is now widely understood by both occupants and investors that this is critically important, as it ensures better indoor climate (IAQ) for occupants, enables certification under BREEAM or LEED, and leads to lower operating costs. These requirements for air handling units and heat recovery systems in ventilation installations are also linked to the requirements of the Energy Performance of Buildings Directive (EPBD 2024/1275), ESG reporting obligations, and the need to ensure a healthy indoor environment for occupants. In many European projects, these standards are already mandatory.

  1. TANGRA’s engineering approach

When developing air handling units and energy recovery units, the TANGRA engineering team follows principles ensuring that the construction complies with VDI 6022 and EN 13053, that easy access is provided for inspection and servicing of every component, that heat recovery efficiency is maximized, that filtration systems and their structural design are of high quality, that fans are IE4 or IE5 class and can be controlled according to the building’s requirements, and that the materials used are durable and reliable. Last but not least, every product is 100% tested before leaving the company’s factory. That is why TANGRA AHU air handling units and TANGRA EVB energy recovery units are used in:

  • Аdministrative and office buildings
  • Manufacturing and industrial facilities
  • Cleanrooms and laboratories
  • Food and beverage industry
  • Electronics and optical industry
  • Hospitals, operating rooms, and various healthcare facilities
  • Public buildings
  • Hotels and SPA centers
  • Industrial and specialized facilities
  • Critical infrastructure facilities in Bulgaria

Hygiene in ventilation systems is not an addition —                                                                                                                                                                                                                                                                    it is a fundamental engineering requirement. The VDI 6022 standard clearly shows that the quality of the air handling unit and the energy recovery unit determines air quality, energy efficiency, reliability, operating costs, and, most importantly, people’s health.